          Surge Backup Protection Circuit Breaker

          NYKU1H-I Series Class T1 (15-25KA)

          NYKU1H Series Class T2 (10-120KA)

          Concise Efficient Safe Comprehensive

          PRODUCT OVERVIEW

          NYKU1H series surge backup protection circuit breakers are mainly used to protect electrical appliances or power equipment from surges. It features fast response and low impedance, and can introduce high voltage and overcurrent to the ground in a very short time to protect the backup equipment and lines, which is especially significant for environments requiring a high degree of reliability and data security.

          PRODUCT CHARACTERISTICS

          Effectiveness

          Compared with conventional MCB protection solutions, the residual voltage at both ends is lower when a surge occurs, thus the equipment can be better protected.

          Accuracy

          When there is lightning current in the SPD, the device will not be mistakenly tripped, ensuring that the lightning protection of electrical equipment is always effective.

          High safety coefficient

          Selectively disconnects the passing industrial frequency current and lightning current, which can effectively avoid SPD from fused short-circuits, and avoid causing serious fire accidents.

          Compliance with the specification requirements

          Complies with national and international electrical safety standards, ensuring legality and reliability and boosting user confidence.

          Technical parameters

          NYKU1H-I series surge backup protection circuit breaker technical parameters

          Model specification NYKU1H-I 15 NYKU1H-I 25
          Rated operating voltage Ue 230V/400V
          Rated insulation voltage Ui 400V
          Number of poles 1P、2P、3P、4P
          Category of adaptation to SPD Category I (T1)
          Waveform 10/350us
          Impulse current limp 15kA 25kA
          Nominal discharge current In 15KA/25kA 15KA/25kA
          Current tripping value Io 3A±1A
          Breaking time of industrial frequency short-circuit current Tos ≤40ms
          Breaking time of industrial frequency load current Tos ≤50ms

          NYKU1H series surge backup protection circuit breaker technical parameters

          Model specification NYKU1H-10 NYKU1H-20 NYKU1H-40kA NYKU1H-60kA
          Rated operating voltage Ue 230V/400V
          Rated insulation voltage Ui 500V
          Number of poles 1P、2P、3P、4P
          Category of adaptation to SPD Category II (T2)
          Waveform 8/20us
          Maximum discharge current Imax 10kA 20kA 40kA 60kA
          Nominal discharge current In 5kA 10kA 20kA 30kA
          Current tripping value Io 3A±1A
          Breaking time of industrial frequency short-circuit current Tos ≤40ms
          Breaking time of industrial frequency load current Tos ≤50ms

          NYKU1H-I Series Surge Backup Protection Circuit Breaker

          Model specification NYKU1H-80kA NYKU1H-100kA NYKU1H-120kA
          Rated operating voltage Ue 230V/400V
          Rated insulation voltage Ui 500V
          Number of poles 1P、2P、3P、4P
          Category of adaptation to SPD Class II(T2)
          Waveform 8/20us
          Maximum discharge current Imax 80kA 100kA 120kA
          Nominal discharge current In 40kA 50kA 60kA
          Current tripping value Io 3A±1A
          Breaking time of industrial frequency short-circuit current Tos ≤40ms
          Breaking time of industrial frequency load current Tos ≤50ms
          Selection table

          NYKU1H-I Series Surge Backup Protection Circuit Breaker

          NYKU1H I 15kA 4P
          Product code Use category Maximum impulse current Number of poles
          NYKU1H:
          Surge Backup Protection Circuit Breaker
          I:Class T1 15kA
          25kA
          1P:1 pole
          2P:2 pole
          3P:3 pole
          4P:4 pole

          NYKU1H SeriesSurge Backup Protection Circuit Breaker

          NYKU1H 10kA 4P
          Product code Maximum discharge current Number of poles
          NYKU1H:
          Surge Backup Protection Circuit Breaker
          10kA
          20kA
          40kA
          60kA
          80kA
          100kA
          120kA
          1P:1 pole
          2P:2 pole
          3P:3 pole
          4P:4 pole

          Technical Parameters


          Surge Backup Protection Circuit Breaker

          • Model specification :NYKU1H-I 15kA/NYKU1H-I 25kA

            Rated operating voltage Ue:230V/400V

            Rated insulation voltage Ui:400V

            Number of poles:1P、2P、3P、4P

            Category of adaptation to SPD:Class I (T1)

            Waveform:10/350us

            Impulse current limp:15kA/25kA

            Nominal discharge current In:15kA、25kA/15kA、25kA

            Current tripping value Io:3A±1A

            Breaking time of industrial frequency short-circuit current Tos:≤40ms

            Breaking time of industrial frequency load current Tos:≤50ms

          • Model specification :NYKU1H- 10kA/NYKU1H-20kA/NYKU1H-40kA/NYKU1H-60kA

            Rated operating voltage Ue:230V/400V

            Rated insulation voltage Ui:500V

            Number of poles:1P、2P、3P、4P

            Category of adaptation to SPD:IClass I (T2)

            Waveform:8/20us

            Maximum discharge current Imax:10kA/20kA/40kA/60kA

            Nominal discharge current In:5kA/10kA/20kA/30kA

            Current tripping value Io:3A±1A

            Breaking time of industrial frequency short-circuit current Tos:≤40ms

            Breaking time of industrial frequency load current Tos:≤50ms

          • Model specification :NYKU1H- 80kA/NYKU1H-100kA/NYKU1H-120kA

            Rated operating voltage Ue:230V/400V

            Rated insulation voltage Ui:500V

            Number of poles: 1P、2P、3P、4P

            Category of adaptation to SPD:IClass I (T2)

            Waveform:8/20us

            Maximum discharge current Imax:80kA/100kA/120kA

            Nominal discharge current In:40kA/50kA/60kA

            Current tripping value Io:3A±1A

            Breaking time of industrial frequency short-circuit current Tos:≤40ms

            Breaking time of industrial frequency load current Tos:≤50ms

          Selection table


          Surge Backup Protection Circuit Breaker

          • Product code :NYKU1H:Surge Backup Protection Circuit Breaker

            Use category:I:Class T1

            Maximum impulse current:15kA、25kA

            Number of poles:1P:1 pole、2P:2 pole、3P:3 pole、4P:4 pole

          • Product code :NYKU1H:Surge Backup Protection Circuit Breaker

            Maximum discharge current :10kA、20kA、40kA、60kA、80kA、100kA、120kA

            Number of poles:1P:1 pole、2P:2 pole、3P:3 pole、4P:4 pole