          Surge Protector

          NYKU1-I series Class T1 (15-50KA)

          NYKU1 series Class T2 (10-160KA)

          Concise Efficient Safe Comprehensive

          PRODUCT OVERVIEW

          NYKU1 series surge protector, also known as lightning protector, is an electrical component capable of suppressing transient overvoltage and lightning strikes. It is mainly installed in circuits to protect electronic equipment from overvoltage and overcurrent.

          PRODUCT CHARACTERISTICS

          Fast response

          Surge protectors are able to react in a very short time (nanoseconds) to ensure that voltage surges are blocked or attenuated before they damage the equipment.

          Low residual voltage,
          high withstand voltage

          It’s conducive to prevent electrical fires caused by excessive voltage by limiting voltage spikes.

          High-energy contacts
          for long service life

          Frequent voltage fluctuations can gradually damage the internal components of load electronic equipment, and surge protectors can minimize the damage and extend the service life of the equipment.

          Small size, full range
          of specification, easy to use

          Modular module meets the mounting requirements of general 35mm guide rail, which is easy to use and maintain.

          Technical Parameters

          NYKU1-I Series Surge Protector Technical Parameters

          Main characteristics
          Execution standard GB/T18802.11/IEC61643-11
          Rated operating voltage Un 230V/400V
          Number of poles 1P、 2P、 3P、 4P
          Experimental type Class I (T1)
          Waveform 10/350us
          Model NYKU1-I 15kA NYKU1-I 25kA NYKU1-I 50kA
          Impulse current limp 15kA 25kA 50kA
          Nominal discharge current In 50kA 50kA 50kA
          Response time Ta ≤100ns ≤100ns ≤100ns
          Maximum continuous operating voltage Uc(V) 275 320 385 440 460 275 320 385 440 460 275 320 385 440 460
          Voltage protection level Up(kV) ≤1.5 ≤1.6 ≤2.0 ≤2.2 ≤2.5 ≤1.8 ≤2.0 ≤2.2 ≤2.4 ≤2.5 ≤2.3 ≤2.5 ≤2.5 ≤3.0 ≤3.2

          NYKU1 Series Surge Protector Technical Parameters

          Main characteristics
          Execution standard GB/T18802.11/IEC61643-11
          Rated operating voltage Un 230V/400V
          Number of poles 1P、1P+N、2P、3P、3P+N、4P
          Experimental type Class II(T2)
          Waveform 8/20us
          Model NYKU1-I 10kA NYKU1-I 20kA NYKU1-I 40kA NYKU1-I 60kA
          Maximum discharge current Imax 10kA 20kA 40kA 60kA
          Nominal discharge current In 5kA 10kA 20kA 30kA
          Response time Ta <25ns <25ns <25ns <25ns
          Maximum continuous operating voltage Uc(V) 275 320 385 460 275 320 385 460 275 320 385 460 275 320 385 460
          Voltage protection level Up(kV) ≤0.8 ≤1.2 ≤1.2 ≤1.2 ≤1.0 ≤1.2 ≤1.4 ≤1.6 ≤1.2 ≤1.4 ≤1.6 ≤2.0 ≤1.5 ≤1.8 ≤1.8 ≤2.2
          Protection degree IP20
          Ambient temperature limit -40℃~80℃
          Installation method 35mm standard electrical guide rail mounted
          Casing color Light grey

          NYKU1 Series Surge Protector Technical Parameters

          Main characteristics
          Execution standard GB/T18802.11/IEC61643-11
          Rated operating voltage Un 230V/400V
          Number of poles 1P、1P+N、2P、3P、3P+N、4P
          Experimental type Class II(T2)
          Waveform 8/20us
          Model NYKU1-I 80kA NYKU1-I 100kA NYKU1-I 120kA NYKU1-I 160kA
          Maximum discharge current Imax 80kA 100kA 120kA 160kA
          Nominal discharge current In 40kA 50kA 60kA 80kA
          Response time Ta <25ns <25ns <25ns <25ns
          Maximum continuous operating voltage Uc(V) 275 320 385 460 385 420 385 420 385 420
          Voltage protection level Up(kV) ≤0.8 ≤1.2 ≤1.2 ≤1.2 ≤2.4 ≤2.5 ≤2.5 ≤2.65 ≤3.0 ≤3.2
          Protection degree IP20
          Ambient temperature limit -40℃~80℃
          Installation method 35mm standard electrical guide rail mounted
          Casing color Light grey
          Selection table

          NYKU1-I Series Surge Protector

          NYKU1 I 15kA 4P 385V Additional features
          Product code Use category Maximum impulse current Number of poles Maximum operating voltage Additional features
          NYKU1:
          Surge Protector
          I:Class T1 15kA
          25kA
          50kA
          1P:1 pole
          2P:2 pole
          3P:3 pole
          4P:4 pole
          275V
          320V
          385V
          440V
          460V
          X:Remote signaling

          Note:NYKU1-I series conventional discharge components are graphite clearance, of which NYKU1-I-15 can be made into two types of discharge components: chip and graphite.
          Remote signaling function is optional for chip type, but not for stands for type. X means remote signaling function, C stands for chip.

          NYKU1 Series Surge Protector

          NYKU1 40kA 4P 385V Additional features
          Product code Maximum discharge current Number of poles Maximum operating voltage Additional features
          NYKU1:
          Surge Protector
          10kA 20kA 40kA 60kA 80kA 100kA 120kA 160kA 1P:1 pole
          1PN:1 pole+N
          2P:2 pole
          3P:3 pole
          3PN:3 pole+N
          4P:4 pole
          275V
          320V
          385V
          460V
          X:Remote signaling

          Technical Parameters


          • Execution standard:GB/T18802.11/IEC61643-11

            Rated operating voltage Un:230V/400V

            Number of poles:1P、2P、3P、4P

            Experimental type:Class I (T1)

            Waveform:10/350us

            Model:NYKU1-I 15kA/NYKU1-I 25kA/NYKU1-I 50kA

            Impulse current limp:15kA/25kA/50kA

            Nominal discharge current In:50kA

            Response time Ta:≤100ms

            Maximum continuous operating voltage Uc(V):275、320、385、440、460

            Voltage protection level Up(kV):≤1.5(275V)、≤1.6(320V) 、≤2.0(385V) 、≤2.2(440V) 、≤2.5(460V) /≤1.8(275V) 、≤2.0(320V) 、≤2.2(385V) 、≤2.4(440V) 、≤2.5(460V) /≤2.3(275V) 、≤2.5(320V) 、≤2.5(385V) 、≤3.0(440V) 、≤3.2(460V)

          • Execution standard:GB/T18802.11/IEC61643-11

            Rated operating voltage Un:230V/400V

            Number of poles:1P、1P+N、2P、3P、3P+N、4P

            Experimental type:IClass I (T2)

            Waveform:8/20us

            Model:NYKU1- 10kA/NYKU1-20kA/NYKU1-40kA/NYKU1-60kA

            Maximum discharge current Imax:10kA/20kA/40kA/60kA

            Nominal discharge current In:5kA/10kA/20kA/30kA

            Response time Ta:<25ns

            Maximum continuous operating voltage Uc(V):275/320/385/460

            Voltage protection level Up(kV):≤0.8(275V)、≤1.2(320V)、≤1.2(385V)、≤1.2(460V)/≤1.0(275V)、≤1.2(320V)、≤1.4(385V)、≤1.6(460V)/≤1.2(275V)、≤1.4(320V)、≤1.6(385V)、≤2.0(460V)/≤1.5(275V)、≤1.8(320V)、≤1.8(385V)、≤2.2(460V)

            Protection degree:IP20

            Ambient temperature limit:-40℃~80℃

            Installation method:35mm standard electrical guide rail mounted

            Casing color:Light grey

          • Execution standard:GB/T18802.11/IEC61643-11

            Rated operating voltage Un:230V/400V

            Number of poles:1P、1P+N、2P、3P、3P+N、4P

            Experimental type:Class II (T2)

            Waveform:8/20us

            Model:NYKU1- 80kA/NYKU1-100kA/NYKU1-120kA/NYKU1-160kA

            Maximum discharge current Imax:80kA/100kA/120kA/160kA

            Nominal discharge current In:40kA/50kA/60kA/80kA

            Response time Ta:<25ns

            Maximum continuous operating voltage Uc(V):275/320/385/420/460

            Voltage protection level Up(KV):≤0.8(275V)、≤1.2(320V)、≤1.2(385V)、≤1.2(460V)/≤2.4(385V)、≤2.5(420V)/≤2.5(385V)、≤2.65(420V)/≤3.0(385V)、≤3.2(420V)

            Protection degree:IP20級(jí)

            Ambient temperature limit:-40℃~80℃

            Installation method:35mm standard electrical guide rail mounted

            Casing color:Light grey

          Selection table


          • Product code :NYKU1: Surge Protector

            Use category:I:Class T1

            Maximum impulse current:15kA、25kA、50AkA

            Number of poles:1P:1 pole、2P:2 pole、3P:3 pole、4P:4 pole

            Maximum operating voltage:275V、320V、385V、440V、460V

            Additional features:X:Remote signaling

          Note:NYKU1-I series conventional discharge components are graphite clearance, of which NYKU1-I-15 can be made into two types of discharge components: chip and graphite.
          Remote signaling function is optional for chip type, but not for stands for type. X means remote signaling function, C stands for chip.

          • Product code :NYKU1: Surge Protector

            Maximum discharge current :10kA、20kA、40kA、60kA、80kA、100kA、120kA、160kA

            Number of poles:1P:1 pole、1PN:1 pole+N、2P:2 pole、3P:3 pole、3PN:3 pole+N、4P:4 pole

            Maximum operating voltage:275V、320V、385V、460V

            Additional features:X:Remote signaling