无码AⅤ在线精品手机版,无码黄片在线播放观看,亚洲春色Av无码专区最,国产精品久久久性色AV

      <b id="rehxw"><address id="rehxw"></address></b>
    1. <b id="rehxw"><tbody id="rehxw"></tbody></b>

          NYKR2 Series

          Thermal Overload Relay

          (25-630A)

          Concise Efficient Safe Comprehensive

          PRODUCT OVERVIEW

          NYKR2 series thermal overload relay is a protection device used to protect motors, and its main function is to detect whether the current of the motor exceeds the rated value during operation. Its working principle is trigger the protection based on the heat generated by the current through its control circuit. When there is an overload, it controls the switching devices to protect the line against overload. The thermal relay can effectively protect the motor from damage under abnormal conditions and prolong the service life of the motor. It’s widely used in industry and other fields, it can realize intelligent control and management.

          PRODUCT CHARACTERISTICS

          Simple and reliable

          Thermal relay has simple structure and it utilizes mechanical action based on the principle of physical thermal expansion, which makes them very reliable with a low fault rate.

          Cost effective

          Compared with other types of protective devices, thermal relays have lower cost and are easy to install and maintain, which are suitable for applications at all scales.

          Automatic reset function

          Most thermal relays can be automatically reset when they cool down to normal temperature after triggering the protective device and being powered off, which is conducive to continuous operation and reduces downtime.

          Time delay

          Thermal relays have an inherent feature of time delay that allows them to wait for a motor to overload in a short period of time, which is useful in avoiding unnecessary and frequent tripping.

          Selective protection

          By appropriately setting the thermal relay, it is possible to respond to a specific current, enhancing the overall protection strategy of the system.

          Environmental adaptability

          Thermal relays are not susceptible to external electromagnetic interference, and its performance enables relatively stable operation under various environmental conditions.

          Technical parameters

          Model NYKR2-F25 NYKR2-F36 NYKR2-F95 NYKR2-F150 NYKR2-F220 NYKR2-F630
          Current rating 25 36 95 150 220 630
          Rated insulation voltage 690V 690V 690V 690V 690V 690V
          Phase failure protection
          Manual and automatic reset
          Temperature compensation
          Tripping indication
          Test button
          Stop button
          Installation method Plug-in or free-standing Plug-in or free-standing Plug-in or free-standing Plug-in or free-standing Free-standing Free-standing
          Auxiliary contact 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC
          Auxiliary circuit AC-15 220V Rated currentA 2.72 2.72 2.72 2.72 2.72 2.72
          AC-15 380V Rated currentA 1.58 1.58 1.58 1.58 1.58 1.58
          AC-13 220V Rated currentA 0.2 0.2 0.2 0.2 0.2 0.2
          Selection table

          NYKR2 F25 Additional features
          Product code Casing grade Additional features
          NYKR2:
          Thermal Overload Relay
          F25
          F36
          F95
          F150
          F220
          F630
          Independent mounting base

          Note: NYKR2-F220, NYKR2-F630 are electronic thermal overload relays, the body adopts free-standing mode without mounting base.
          NYKR2-F150 mounting base (free-standing) is independently guide rail mounted with NYKR2-F150 body, NYKR2-F150 mounting base (combined) is mounted in combination with NYKR2-F150 body, and can be directly connected with NYKC2-115, NYKC2-150 AC contactors.

          Technical Parameters


          NYKR2 SeriesThermal Overload Relay

          • Current rating:25

            Rated insulation voltage :690V

            Phase failure protection:Standard configuration

            Manual and automatic reset:Standard configuration

            Temperature compensation:Standard configuration

            Tripping indication:Standard configuration

            Test button:Standard configuration

            Stop button:Standard configuration

            Installation method:Plug-in or free-standing

            Auxiliary contact:1NO+1NC

            Auxiliary circuitAC-15 220V Rated current:2.72A

            Auxiliary circuitAC-15 380V Rated current:1.58A

            Auxiliary circuitDC-13 220V Rated current:0.2A

          • Current rating:36

            Rated insulation voltage :690V

            Phase failure protection:Standard configuration

            Manual and automatic reset:Standard configuration

            Temperature compensation:Standard configuration

            Tripping indication:Standard configuration

            Test button:Standard configuration

            Stop button:Standard configuration

            Installation method:Plug-in or free-standing

            Auxiliary contact:1NO+1NC

            Auxiliary circuitAC-15 220V Rated current:2.72A

            Auxiliary circuitAC-15 380V Rated current:1.58A

            Auxiliary circuitDC-13 220V Rated current:0.2A

          • Current rating:95

            Rated insulation voltage :690V

            Phase failure protection:Standard configuration

            Manual and automatic reset:Standard configuration

            Temperature compensation:Standard configuration

            Tripping indication:Standard configuration

            Test button:Standard configuration

            Stop button:Standard configuration

            Installation method:Plug-in or free-standing

            Auxiliary contact:1NO+1NC

            Auxiliary circuitAC-15 220V Rated current:2.72A

            Auxiliary circuitAC-15 380V Rated current:1.58A

            Auxiliary circuitDC-13 220V Rated current:0.2A

          • Current rating:150

            Rated insulation voltage :690V

            Phase failure protection:Standard configuration

            Manual and automatic reset:Standard configuration

            Temperature compensation:Standard configuration

            Tripping indication:Standard configuration

            Test button:Standard configuration

            Stop button:Standard configuration

            Installation method:Plug-in or free-standing

            Auxiliary contact:1NO+1NC

            Auxiliary circuitAC-15 220V Rated current:2.72A

            Auxiliary circuitAC-15 380V Rated current:1.58A

            Auxiliary circuitDC-13 220V Rated current:0.2A

          • Current rating:220

            Rated insulation voltage :690V

            Phase failure protection:Standard configuration

            Manual and automatic reset:Standard configuration

            Temperature compensation:Standard configuration

            Tripping indication:Standard configuration

            Test button:Standard configuration

            Stop button:Standard configuration

            Installation method:Plug-in or free-standing

            Auxiliary contact:1NO+1NC

            Auxiliary circuitAC-15 220V Rated current:2.72A

            Auxiliary circuitAC-15 380V Rated current:1.58A

            Auxiliary circuitDC-13 220V Rated current:0.2A

          • Current rating:630

            Rated insulation voltage :690V

            Phase failure protection:Standard configuration

            Manual and automatic reset:Standard configuration

            Temperature compensation:Standard configuration

            Tripping indication:Standard configuration

            Test button:Standard configuration

            Stop button:Standard configuration

            Installation method:Plug-in or free-standing

            Auxiliary contact:1NO+1NC

            Auxiliary circuitAC-15 220V Rated current:2.72A

            Auxiliary circuitAC-15 380V Rated current:1.58A

            Auxiliary circuitDC-13 220V Rated current:0.2A

          Selection table


          • Product code :NYKR2:Thermal Overload Relay

            Casing grade:F25、F36、F95、F150、F220、F630

            Additional features:Independent mounting base

          Note: NYKR2-F220, NYKR2-F630 are electronic thermal overload relays, the body adopts free-standing mode without mounting base.
          NYKR2-F150 mounting base (free-standing) is independently guide rail mounted with NYKR2-F150 body, NYKR2-F150 mounting base (combined) is mounted in combination with NYKR2-F150 body, and can be directly connected with NYKC2-115, NYKC2-150 AC contactors.

          page top