          KLD-BMS Series

          Harmonic Protector

          Harmonic control product developed for precise instruments on the user side that are susceptible to various kinds of interferences and result in various faults. It can absorb high-frequency pulse spike and high-frequency noise signals to protect sensitive equipment on the user side.

          PRODUCT OVERVIEW

          As science and technology continues to develop, harmonics generated by nonlinear modern power equipment and devices, such as computers, lighting control systems, communication systems, network control equipment, a variety of digital office equipment, light regulation and control systems, UPS, CNC machine tools, rectifiers, precise instruments, electronic control mechanisms, etc., result in a harsh harmonic environment, posing s great threat to the normal operation of the power system and equipment. The microprocessors in electronic equipment, automatic control equipment and computers are usually more sensitive and have higher requirements for harmonic environments.

          KLD-BMS series harmonic protector can absorb harmonic interferences of various frequencies and energies. Eliminating the occurrence of harmonics at the source can automatically eliminate the random high-order harmonics and high frequency noise, pulse spike, surge and other interferences to the power equipment. Harmonic protector can purify the power supply, protect the power equipment and power factor compensation equipment, prevent the false tripping of the protection device, so as to improve the operation efficiency and reliability of the equipment, reduce the cost of equipment maintenance and repair, and prolong the service life of the equipment.

          EFFECTIVE PROTECTION AGAINST
          HIGH-FREQUENCY INTERFERENCE

          ●   Provide harmonic protection of various energies at frequencies of 1KHz-20MHz, eliminating high-order harmonics, high-frequency noise, pulse spikes, surges and other interferences.

          ●   Reduce the fault rate and misoperation of control equipment and other precise instruments to overcome the high-frequency interference caused by harmonic pollution.

          ●   Simple wiring, diverse installation positions, convenient commissioning, without routine maintenance.

          Technical Parameters

          Rated voltage 110V~690V
          Rated frequency 50Hz/60Hz
          Protection frequency 1kHz~20MHz
          Protection range Pulse withstand current≤16000A Single loop high-order harmonics(n≥20)Harmonic current≤40A
          Response time Instantaneous response time≤100us,full response time≤10ms
          Instantaneous withstand voltage Pulse withstand voltage2500V
          Leakage current ≤1.321mA
          Power consumption <0.1W
          Overload protection Supported, with front circuit breaker
          Protection degree IIP40/P54 kit can be retrofitted
          Installation method Guide rail mounted
          Altitude Conventional 2000 meters, higher altitude can be customized
          Relative humidity ≤95%RH(no condensing)
          Storage temperature -50℃~+90℃
          Temperature range -35℃~+80℃
          Execution standard IEC61000-4-5, EC60939-1-2
          GB14549-93 Quality of electric energy supply Harmonics in public supply network
          GB12325-90 Quality of electric energy supply Admissible deviation of supply voltage
          Selection table

          Model Voltage(V) Installation method Protection frequency
          KLD-BMS99-3-400V 400 Guide rail mounted 1kHz-20MHz
          KLD-BMS100-3-400V 400 Guide rail mounted 1kHz-20MHz
          KLD-BMS300-3-400V 400 Guide rail mounted 1kHz-20MHz
          KLD-BMS500-3-400V 400 Guide rail mounted 1kHz-20MHz
          KLD-BMS1000-3-400V 400 Guide rail mounted 1kHz-20MHz
          KLD-BMS1000E-3-400V 400 Guide rail mounted 1kHz-20MHz

          Technical Parameters


          • Rated voltage:110V~690V

            Rated frequency:50Hz/60Hz

            Protection frequency:1kHz~20MHz

            Protection range:Pulse withstand current≤16000A Single loop high-order harmonics(n≥20)Harmonic current≤40A

            Response time:Instantaneous response time≤100us,full response time≤10ms

            Instantaneous withstand voltage:Pulse withstand voltage2500V

            Leakage current:≤1.321mA

            Power consumption:<0.1W

            Overload protection:Provided,with front circuit breaker

            Protection degree:IIP40/P54 kit can be retrofitted

            Installation method:Guide rail mounted

            Altitude:Conventional 2000 meters, higher altitude can be customized

            Relative humidity:≤95%RH(no condensing)

            Storage temperature:-50℃~+90℃

            Temperature range:-35℃~+80℃

            Execution standard:IEC61000-4-5, EC60939-1-2;GB14549-93 Quality of electric energy supply Harmonics in public supply network;GB12325-90 Quality of electric energy supply Admissible deviation of supply voltage

          Selection table


          • KLD-BMS99-3-400V

            Voltage(V):400

            Installation method:Guide rail mounted

            Protection frequency:1kHz-20MHz

            KLD-BMS100-3-400V

            Voltage(V):400

            Installation method:Guide rail mounted

            Protection frequency:1kHz-20MHz

            KLD-BMS300-3-400V

            Voltage(V):400

            Installation method:Guide rail mounted

            Protection frequency:1kHz-20MHz

            KLD-BMS500-3-400V

            Voltage(V):400

            Installation method:Guide rail mounted

            Protection frequency:1kHz-20MHz

            KLD-BMS1000-3-400V

            Voltage(V):400

            Installation method:Guide rail mounted

            Protection frequency:1kHz-20MHz

            KLD-BMS1000E-3-400V

            Voltage(V):400

            Installation method:Guide rail mounted

            Protection frequency:1kHz-20MHz

          page top