          NYKP Series

          Dual Power Automatic Transfer Switch

          NYKP2 series(16A-3200A)

          NYKP1 series(6A-630A)

          Intelligent Fast Safe Comprehensive

          PRODUCT OVERVIEW

          Dual power automatic transfer switch is a power conversion equipment, featuring fast response, strong stability and high reliability; it has the protection functions for short circuit, grounding, phase loss and over-voltage; widely used in power plants, substations, coal mines, ports, factories, airports, and other important places for the protection of circuits and equipment safety, realizing intelligent control and management.

          FAST RESPONSE AND SWITCHING

          Dual power supplies are driven by motors and solenoids for fast.

          ISOLATION FUNCTION MAKES USERS MORE ASSURED

          The front end of the product can be set with an isolation switch or with isolation function,providing obvious line disconnection points to protect personal safety during maintenance.

          TECHNICAL PARAMETERS

          NYKP2 Series

          • Rated operating voltage: 400V
          • Rated operating current: 16-3200A
          • Product category: PC grade
          • Number of poles: 2P, 3P, 4P
          • Switching mode: automatic charge and automatic recovery, automatic charge without automatic recovery
          • Power supply mode: grid - grid, grid - power generation
          • Use category: AC-33iB, AC-33B

          NYKP1 series

          • Rated operating voltage: 400V
          • Rated operating current: 6-630A
          • Product category: CB grade
          • Number of poles: 3P, 4P
          • Switching mode: automatic charge and automatic recovery, automatic charge without automatic recovery
          • Power supply mode: grid - grid, grid - power generation
          • Use category: AC-33iB
          Technical Parameters

          NYKP2-G Series DUAL Power Supply

          Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Number of poles Rated short-circuit making capacity Icm(kA)Icm(kA) Rated short-time withstand current Icw (kA) Icw(kA) Use category
          NYKP2-GA AC400 100 16、20、25、32、40、50、63、80、100 3P、4P 8 5kA/30ms AC-33B
          NYKP2-GA 250 125、160、200、225、250 10kA/60ms
          NYKP2-GA 630 315、350、400、500、630 12.6kA/60ms
          NYKP2-GA 1600 800、1000、1250、1600 32kA/60ms AC-33iB
          NYKP2-GA 3200 2000、2500、3200 50kA/1s

          NYKP2-LA/L/SA/S Series DUAL Power Supply

          Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Number of poles Rated short-circuit making and Breaking capacity Icm(kA) Operation cycles times/hour Rated short-time withstand current Icw (kA) Icw(kA) Use category
          NYKP2-SA、S、LA、L AC230V(2P), AC400V(3P、4P) 125 20、32、40、50、63、80、 100、125 2P、3P、4P 25 120 10kA/30ms AC-33B
          NYKP2-SA、S、LA、L 250 125、160、200、250 2P、3P、4P 25 10kA/30ms AC-33B
          NYKP2-SA、S、LA、L 630 250、315、400、500、630 2P、3P、4P 30 12.6kA/60ms AC-33B

          NYKP2 Series DUAL Power Controller Summary

          Controller Model NYKP2 Series
          Product model y-701 y-702
          Installation method Split type
          Display mode Indicator light display LCD display
          Rated working system Uninterrupted working system
          Automatic charge and automatic recovery
          Automatic charge without automatic recovery
          Mutual backup
          Automatic start generator function
          Common power supply detection Four-phase power loss detection, three-phase over-voltage and
          Backup power supply detection Four-phase power loss detection, three-phase over-voltage and
          Passive fire protection input
          Active fire protection input (DC9-36V)(DC9-36V)
          Adjustable transfer delay
          Real-time voltage display
          Common and backup power supply indication
          Adjustable overvoltage and undervoltage for common and backup power
          Adjustable start and stop time of generator ●(F/F1)
          Programmable output port
          RS485Electrical energy measurement

          NYKP1 Series DUAL Power Supply

          Model Rated operating voltage Ue(V) Rated impulse withstand voltage Uimp(kV) Casing current Inm(A) Rated currentIn(A) Number of poles Rated short-circuit breaking capacity Icn (kA) Rated short-circuit making capacity Icm(kA)Icm(kA) Product code Use category
          NYKP1 AC400 8 63 6、10、16、20、25、 32、40、50、63 3P、4P 5 120 M:Basic type M1: Fire extinguishing type AC-33iB

          NYKP1A Series DUAL Power Supply

          Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Number of poles Operating mode Transfer time Mechanical life(Times) Electrical life (times) Controller
          NYKP1A AC400 63 6、10、16、20、25、 32、40、50、63 4P R(Automatic charge and automatic recovery)
          S(Automatic charge without automatic recovery)
          F(grid-power generation)
          ≤2s 10000 4500
          NYKP1A 125 63、80、100、125 ≤3s+delay time 7000 3000 W2
          W3
          NYKP1A 250 160、180、200、225、250 5000 2000
          NYKP1A 630 315、350、400、500、630 5000 2000

          NYKP1 Series Dual Power Controller Summary

          Product model NYKP1 Series
          Controller Model W2 W3
          Installation method Split type
          Display mode Digital display LCD display
          Rated working system
          Automatic charge and automatic recovery
          Automatic charge without automatic recovery
          Mutual backup
          Automatic start generator function
          Common power supply detection
          Backup power supply detection
          Passive fire protection input
          Active fire protection input (DC9-36V)(DC9-36V)
          Adjustable transfer delay
          Real-time voltage display
          Common and backup power supply indication
          Adjustable overvoltage and undervoltage for common and backup power
          Adjustable start and stop time of generator
          Programmable output port
          RS485Electrical energy measurement
          Selection table

          NYKP2-G Series DUAL Power Supply

          NYKP2 100 GA 4P 100A RF Additional functions
          Product code Casing current Product category Pole No. Rated current Operating mode Additional functions
          NYKP2:
          Dual power automatic transfer switch
          100A
          250A
          630A
          1600A
          3200A
          GA: Electric motor type
          GA1: Electric motor type
          3P:3 pole
          4P:4 pole
          16A、20A
          25A、32A
          40A、50A
          63A、80A
          100A、125A
          160A、200A
          225A、250A
          315A、350A
          400A、500A
          630A、800A
          1250A
          1600A
          2000A
          2500A
          3200A
          R:Automatic charge and automatic recovery
          S:Automatic charge without automatic recovery
          F:Grid generation
          RF:Automatic charge and automatic recovery+Grid generation
          Y-701
          Y-702

          NYKP2-LA/L/SA/S Series DUAL Power Supply

          NYKP2 125 SA 4P 100A RF Additional functions
          Product code Casing current Product category Pole No. Rated current Operating mode Additional functions
          NYKP2:
          Dual power automatic transfer switch
          125A
          250A
          630A
          SA: Integrated three-section type
          LA: Integrated two-section type
          S:Split three-section type
          L:Split two-section type
          2P:2 pole
          3P:3 pole
          4P:4 pole
          20A、32A、 40A、
          50A、 63A、80A、
          100A、125A、 160A、
          200A、 250A、315A、
          400A、500A、630A
          R:Automatic charge and automatic recovery
          S:Automatic charge without automatic recovery
          F:Grid generation
          RF:Automatic charge and automatic recovery+Grid generation
          Y-701
          Y-702

          Note:?  GA series equipped with standard fire protection function
          ?  GA1 series does not include fire protection function
          ?  GA series with automatic charge without automatic recovery function should be equipped with Y-701/Y-702 controller
          ?   GA series with communication function should be equipped with Y-702 controller

          NYKP1 Series DUAL Power Supply

          NYKP1 63 M 3P 63A RF C type
          Product code Casing current Product category Pole No. Rated current Operating mode Tripping type
          NYKP1:
          Dual power automatic transfer switch
          63A Model M:Basic type
          M1 type:Fire protection type
          3P:3 pole
          4P:4 pole
          6A、10A、 16A、
          20A、 25A、32A、
          40A、50A、 63A
          R:Automatic charge and automatic recovery
          S:Automatic charge without automatic recovery
          F:Grid generation
          RF:Automatic charge and automatic recovery+Grid generation
          C type
          D type

          Note: KLDCB1 is a CB grade dual power supply switch, the execution unit is a miniature circuit breaker, with C characteristics by default

          NYKP1A Series DUAL Power Supply

          NYKP1A 125 4P 63A RF Additional functions
          Product code Casing current Pole No. Rated current Operating mode Additional functions
          NYKP1A:
          Dual power automatic transfer switch
          63A
          125A
          250A
          630A
          4P:4 pole 6A、10A
          16A、20A
          25A、32A
          40A、50A
          63A、80A
          100A、125A
          160A、180A
          200A、225A
          250A、315A
          350A、400A
          500A、630A
          R:Automatic charge and automatic recovery
          S:Automatic charge without automatic recovery
          F:Grid generation
          RF:Automatic charge and automatic recovery+Grid generation
          W2
          W3
          T:Electrical energy measurement

          Note: The execution unit of NYKP1A is a miniature circuit breaker, with C characteristics by default. others are molded case circuit breaker.

          Technical Parameters

          NYKP2-G Series DUAL Power Supply

          • Rated operating voltage (V):AC400

            Current shell frame Inm (A) :16、20、25、32、40、50、63、80、100

            Number of poles:3P、4P

            Rated short-circuit making capacity Icm(kA)lcm(kA):8

            Rated short-time withstand current Icw (kA) Icw(kA):5kA/30ms

            Use category:AC-33B

          • Rated operating voltage (V):AC400

            Current shell frame Inm (A) :125、160、200、225、250

            Number of poles:3P、4P

            Rated short-circuit making capacity Icm(kA)lcm(kA):8

            Rated short-time withstand current Icw (kA) Icw(kA):10kA/60ms

            Use category:AC-33B

          • Rated operating voltage (V):AC400

            Current shell frame Inm (A) :315、350、400、500、630

            Number of poles:3P、4P

            Rated short-circuit making capacity Icm(kA)lcm(kA):8

            Rated short-time withstand current Icw (kA) Icw(kA):12.6kA/60ms

            Use category:AC-33B

          • Rated operating voltage (V):AC400

            Current shell frame Inm (A) :800、1000、1250、1600

            Number of poles:3P、4P

            Rated short-circuit making capacity Icm(kA)lcm(kA):8

            Rated short-time withstand current Icw (kA) Icw(kA):32kA/60ms

            Use category:AC-33iB

          • Rated operating voltage (V):AC400

            Current shell frame Inm (A) :2000、2500、3200

            Number of poles:3P、4P

            Rated short-circuit making capacity Icm(kA)lcn(kA):8

            Rated short-time withstand current Icw (kA) Icw(kA):50kA/1s

            Use category:AC-33iB

          NYKP2-LA/L/SA/S Series DUAL Power Supply

          • Rated operating voltage (V):AC230V(2P),AC400V(3P、4P)

            Current shell frame Inm (A) :20、32、40、50、63、80、100、125

            Number of poles:2P、3P、4P

            Rated short-circuit making and breaking capacityIcm (kA) lcm(kA):25

            Operation cycles times/hour:120

            Rated short-time withstand current Icw (kA) Icw(kA):10kA/30ms

            Use category:AC-33iB

          • Rated operating voltage (V):AC230V(2P),AC400V(3P、4P)

            Current shell frame Inm (A) :125、160、200、250

            Number of poles:2P、3P、4P

            Rated short-circuit making and breaking capacityIcm (kA) lcm(kA):25

            Operation cycles times/hour:120

            Rated short-time withstand current Icw (kA) Icw(kA):10kA/30ms

            Use category:AC-33iB

          • Rated operating voltage (V):AC230V(2P),AC400V(3P、4P)

            Current shell frame Inm (A) :250、315、400、500、630

            Number of poles:2P、3P、4P

            Rated short-circuit making and breaking capacityIcm (kA) lcm(kA):30

            Operation cycles times/hour:120

            Rated short-time withstand current Icw (kA) Icw(kA):12.6kA/60ms

            Use category:AC-33iB

          NYKP2 Series Dual Power Controller Summary

          • Installation method:Split type

            Display mode:Indicator light display

            Rated working system:Uninterrupted working system

            Automatic charge and automatic recovery:have

            Automatic charge without automatic recovery:have

            Mutual backup:have

            Automatic start generator function:have

            Common power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

            Backup power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

            Passive fire protection input:have

            Active fire protection input (DC9-36V):have

            Adjustable transfer delay:have

            Real-time voltage display:not have

            Common and backup power supply indication:have

            Adjustable overvoltage and undervoltage for common and backup power:have

            Adjustable start and stop time of generator:have

            Programmable output port:not have

            RS485 communication function:not have

          • Installation method:Split type

            Display mode:LCD display

            Rated working system:Uninterrupted working system

            Automatic charge and automatic recovery:have

            Automatic charge without automatic recovery:have

            Mutual backup:have

            Automatic start generator function:have

            Common power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

            Backup power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

            Passive fire protection input:have

            Active fire protection input (DC9-36V) :have

            Adjustable transfer delay:have

            Real-time voltage display:have

            Common and backup power supply indication:have

            Adjustable overvoltage and undervoltage for common and backup power:have

            Adjustable start and stop time of generator:have(F/F1)

            Programmable output port:have

            RS485 communication function:have

          NYKP1 Series DUAL Power Supply

          • Rated operating voltage (V):AC400V

            Rated impulse withstand voltage Uimp(kV):8

            Current shell frame Inm (A) :6、10、16、20、25、32、40、50、63

            Number of poles:3P、4P

            Rated ultimate breaking capacity lcm(kA):5

            Rated short-circuit making capacity Icm(kA)lcn(kA):120

            Product code :M: Basic type M1: Fire extinguishing type

            Use category:AC-33iB

          NYKP1A Series DUAL Power Supply

          • Rated operating voltage (V):AC400V

            Rated impulse withstand voltage Uimp(kV):8

            Current shell frame Inm (A) :6、10、16、20、25、32、40、50、63

            Number of poles:4P

            Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

            Transfer time:≤2s

            Mechanical life (times) :10000

            Electrical life (times) :4500

          • Rated operating voltage (V):AC400V

            Rated impulse withstand voltage Uimp(kV):8

            Current shell frame Inm (A) :63、80、100、125

            Number of poles:4P

            Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

            Transfer time:≤3s+delay time

            Mechanical life (times) :7000

            Electrical life (times) :3000

            Controller:W2、W3

          • Rated operating voltage (V):AC400V

            Rated impulse withstand voltage Uimp(kV):8

            Current shell frame Inm (A) :160、180、200、225、250

            Number of poles:4P

            Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

            Transfer time:≤3s+delay time

            Mechanical life (times) :5000

            Electrical life (times) :2000

            Controller:W2、W3

          • Rated operating voltage (V):AC400V

            Rated impulse withstand voltage Uimp(kV):8

            Current shell frame Inm (A) :315、350、400、500、630

            Number of poles:4P

            Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

            Transfer time:≤3s+delay time

            Mechanical life (times) :5000

            Electrical life (times) :2000

            Controller:W2、W3

          NYKP1 Series Dual Power Controller Summary

          • Installation method:Split type

            Display mode:Digital display

            Rated working system:not have

            Automatic charge and automatic recovery:have

            Automatic charge without automatic recovery:have

            Mutual backup:have

            Automatic start generator function:have

            Common power supply detection:have

            Backup power supply detection:have

            Passive fire protection input:have

            Active fire protection input (DC9-36V) :have

            Adjustable transfer delay:have

            Real-time voltage display:have

            Common and backup power supply indication:have

            Adjustable overvoltage and undervoltage for common and backup power:have

            Adjustable start and stop time of generator:have

            Programmable output port:have

            RS485 communication function:have

          • Installation method:Split type

            Display mode:LCD display

            Rated working system:not have

            Automatic charge and automatic recovery:have

            Automatic charge without automatic recovery:have

            Mutual backup:have

            Automatic start generator function:have

            Common power supply detection:have

            Backup power supply detection:have

            Passive fire protection input:have

            Active fire protection input (DC9-36V):have

            Adjustable transfer delay:have

            Real-time voltage display:have

            Common and backup power supply indication:have

            Adjustable overvoltage and undervoltage for common and backup power:have

            Adjustable start and stop time of generator:have

            Programmable output port:have

            RS485 communication function:have

          Selection table


          NYKP2-G Series DUAL Power Supply

          • Product code :NYKP2: Dual power automatic transfer switch

            Current shell frame :100A、250A、630A、1600A、3200A

            Product category :GA、GA1

            Pole code :3P、4P

            Rated current:16A、20A、25A、32A、40A、50A、63A、80A、100A、125A、160A、200A、225A、250A、315A、350A、400A、500A、630A、800A、1250A、1600A、2000A、2500A、3200A

            Operating mode :R:Automatic charge and automatic recovery、S:Automatic charge without automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

            Additional features:Y-701、Y-702

          NYKP2-LA/L/SA/S Series DUAL Power Supply

          • Product code :NYKP2: Dual power automatic transfer switch

            Current shell frame :125A、250A、630A

            Product category:SA:Integrated three-section type、LA: Integrated two-section type 、S: Split three-section type、L:Split two-section type

            Pole code :2P、3P、4P

            Rated current: 20A、32A、40A、50A、63A、80A、100A、125A、160A、200A、250A、315A、400A、500A、630A

            Operating mode :R:Automatic charge and automatic recovery、S:Automatic charge without automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

            Additional features:Y-701、Y-702

          Note: GA series equipped with standard fire protection function
          GA1 series does not include fire protection function
          GA series with automatic charge without automatic recovery function should be equipped with Y-701/Y-702 controller
          GA series with communication function should be equipped with Y-702 controller

          NYKP1 Series DUAL Power Supply

          • Product code :NYKP1: Dual power automatic transfer switch

            Current shell frame :63A

            Product category:Type M: Basic type、Type M1: Fire protection type

            Pole code :3P、4P

            Rated current:6A、10A、16A、20A、32A、40A、50A、63A

            Operating mode :R:Automatic charge and automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

            Tripping type:Type C 、Type D

          Note: KLDCB1 is a CB grade dual power supply switch, the execution unit is a miniature circuit breaker, with C characteristics by default

          NYKP1A Series DUAL Power Supply

          • Product code :NYKP1A: Dual power automatic transfer switch

            Current shell frame :63A、125A、250A、630A

            Pole code :4P

            Rated current:6A、10A、16A、20A、32A、40A、50A、63A、80A、100A、125A、160A、180A、200A、225A、250A、315A、350A、400A、500A、630A

            Operating mode :R:Automatic charge and automatic recovery、S:Automatic charge without automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

            Additional features:W2、W3、T: Communication function

          Note: The execution unit of NYKP1A is a miniature circuit breaker, with C characteristics by default. others are molded case circuit breaker.