          DSCPS Series

          Control and Protection Switch

          (1-125A)

          Concise Efficient Safe Comprehensive

          PRODUCT OVERVIEW

          DSCPS series control and protection switch is a comprehensive intelligent product integrating various functions of circuit breaker (fuse), contactor, overload (overcurrent, phase failure) protection relay, starter, isolator, etc. It can protect the system from short-circuit, overload, and leakage protection, and it is widely used in industry and other fields to protect the circuits and realize intelligent control and management.

          MULTIPLE PROTECTION FUNCTIONS

          D5CPS series control and protection switch has many functions such as phase failure, overcurrent, locked rotor, blockage, short circuit, undercurrent, overvoltage, undervoltage, residual current protection, three-phase unbalance, phase loss, isolation, startup timeout, fire protection, fault signal output, and remote shunt, etc., providing electrical protection for the equipment.

          FAULT MEMORY FUNCTION

          DSCPS series control and protection switch has the functions of remote automatic control and local direct manual control. Various parameters can be set and queried; based on MCU's ERPROM storage memory technology, parameters can be saved after power failure. It has a fault memory function, which is convenient for fault query and analysis.

          Technical parameters

          DSCPS series control and protection switch technical parameters

          Shell frame grade Rated current
          of main body
          Breaking Casing grade
          capacity (kA)
          Rated operating
          current of
          controller Ie (A)
          Rated operating
          current adjustment
          range of
          controller Ir (A)
          Control power range of
          400V (kW) (kW)
          Use category
          45 16 15 1 0.2-1 0.12-0.37 Motor type AC-44
          3 1-3 0.55-1.5
          6 2.4-6 1.1-3
          10 4-10 1.5-4
          16 6.4-16 3-7.5
          45 20 10-20 5.5-11
          32 12.8-32 5.5-15
          45 16-45 7.5-18.5
          125 125 35 50 20-50 7.5-22
          63 25.2-63 11-30
          80 32-80 16-37
          100 40-100 22-45
          125 50-125 22-55

          DSCPS2 series control and protection switch technical parameters

          Shell frame grade Rated current of
          main body
          Breaking capacity(kA) Rated operating current
          of controller Ie (A)
          Rated operating
          current adjustment
          range of controller Ir (A)
          Control power
          range of 400V (kW) (kW)
          Use category
          45 16 50kA 1 0.2-1 0.12-0.37 Motor type AC-44
          4 1-4 0.55-1.5
          6.3 2.4-6.3 1.1-3
          12 4-12 1.5-4
          16 6.4-16 3-7.5
          45 32 12.8-32 5.5-15
          45 16-45 7.5-18.5
          125 63 45 18-45 7.5-18.5
          50 20-50 7.5-22
          63 25.2-63 11-30
          125 100 40-100 22-37
          125 50-125 22-55
          Selection table

          DSCPS Series Control and Protection Switch

          DSCPS 45 H 33 M 45 FK M B F
          Product code Shell frame
          grade
          Breaking
          capacity (kA)
          Number of
          poles and
          protection
          Tripping
          device code
          Rated
          current
          Auxiliary
          code
          Control
          voltage
          Display
          code
          Additional
          features
          DSCPS:
          Control and Protection Switch
          45A
          125A
          Ics:15kA
          Ics:35kA
          33: 3 pole 3 protection
          30:3 pole without protection
          M: Motor protection1A
          3A
          6A
          10A
          16A
          20A
          32A
          45A
          50A
          63A
          80A
          100A
          125A
          FK: 4 opened, 3 closed
          + 1 group conversion
          + 1 group fault alarm
          + 1 group short-circuit alarm
          M:AC220V B:Digital F:Fire protection
          L:Leakage
          FL:Fire protection+Leakage

          Note: Isolation function is standard setting

          DSCPS2 Series Control and Protection Switch

          DSCPS2 45 H 33 M 45 FK M B F
          Product code Shell frame
          grade
          Breaking capacity (kA) Number of
          poles and
          protection
          Tripping
          device code
          Rated current Auxiliary
          code
          Control voltage Display code Additional
          features
          DSCPS2:
          Control and Protection Switch
          45A
          125A
          Ics:50kA 33: 3 pole 3 protection
          30:3 pole without protection
          M: Motor protection 1A
          4A
          6.3A
          12A
          16A
          32A
          45A
          50A
          63A
          100A
          125A
          FK: 2 opened and 2 closed
          + 1 group conversion
          + 1 group short-circuit alarm
          M:AC220V B:Digital
          E:LCD
          F:Fire protection
          L:Leakage
          T:Communication
          FT:Fire protection+Communication
          TL:Communication+Leakage
          FLT:Fire protection+Leakage +Communication

          Note: Isolation function is standard setting, fire protection and leakage function are optional.

          Technical Parameters


          DSCPS Series Control and Protection Switch

          • Rated current of main body:16

            Breaking capacity (kA) :15kA

            Rated operating current of controller Ie (A) :1A、3A、6A、10A、16A

            Rated operating current adjustment range of controller Ir (A) :0.2-1A、1-3A、2.4-6A、4-10A、6.4-16A

            Control power range of 400V (kW) :0.12-0.37kW、0.55-1.5kW、1.1-3kW、1.5-4kW、3.7-5kW

            Use category: Motor type AC-44

          • Rated current of main body :45

            Breaking capacity (kA) :15kA

            Rated operating current of controller Ie (A) :20A、32A、45A

            Rated operating current adjustment range of controller Ir (A) :10-20A、12.8-32A、16-45A

            Control power range of 400V (kW) :5.5-11kW、5.5-15kW、7.8-18.5kW

            Use category: Motor type AC-44

          • Rated current of main body :125

            Breaking capacity (kA) :35kA

            Rated operating current of controller Ie (A) :50A、63A、80A、100A、125A

            Rated operating current adjustment range of controller Ir (A) :20-50A、25.2-63A、32-80A、40-100A、50-125A

            Control power range of 400V (kW) :7.5-22kW、11-30kW、16-37kW、22-45kW、22-55kW

            Use category: Motor type AC-44

          DSCPS2 Series Control and Protection Switch

          • Rated current of main body :16

            Breaking capacity (kA) :50kA

            Rated operating current of controller Ie (A) :1A、4A、6.3A、12A、16A

            Rated operating current adjustment range of controller Ir (A) :0.2-1A、1-4A、2.4-6A、4-12A、6.4-16A

            Control power range of 400V (kW) :0.12-0.37kW、0.55-1.5kW、1.1-3kW、1.5-4kW、3.7-5kW

            Use category: Motor type AC-44

          • Rated current of main body :45

            Breaking capacity (kA) :50kA

            Rated operating current of controller Ie (A) :32A、45A

            Rated operating current adjustment range of controller Ir (A) :12.8-32A、16-45A

            Control power range of 400V (kW) :5.5-15kW、7.8-18.5kW

            Use category: Motor type AC-44

          • Rated current of main body :63

            Breaking capacity (kA) :50kA

            Rated operating current of controller Ie (A) :45A、50A、63A

            Rated operating current adjustment range of controller Ir (A) :18-45A、20-50A、25.2-63A

            Control power range of 400V (kW) :7.8-18.5kW、7.5-22kW、11-30kW

            Use category: Motor type AC-44

          • Rated current of main body :125

            Breaking capacity (kA) :50kA

            Rated operating current of controller Ie (A) :100A、125A

            Rated operating current adjustment range of controller Ir (A) :40-100A、22-37A

            Control power range of 400V (kW) :22-37kW、22-55kW

            Use category: Motor type AC-44

          Selection table


          • Product code :DSCPS: Control and Protection Switch

            Casing grade:45A、125A

            Breaking capacity (kA) :Ics:15kA、Ics:35kA

            Number of poles and protection:33: 3 pole 3 protection 、30:3 pole without protection

            Tripping device code:M: Motor protection

            Rated current:1A、3A、6A、10A、16A、20A、32A、45A、50A、63A、80A、100A、125A

            Auxiliary code:FK: 4 opened, 3 closed+ 1 group conversion + 1 group fault alarm + 1 group short-circuit alarm

            Control voltage:M:AC220V

            Display code:B:Digital

            Additional features:F:Fire protection、L:Leakage 、FL:Fire protection+Leakage

          • Product code :DSCPS2: Control and Protection Switch

            Casing grade:45A、125A

            Breaking capacity (kA) :Ics:50kA

            Number of poles and protection:33: 3 pole 3 protection 、30:3 pole without protection

            Tripping device code:M: Motor protection

            Rated current:1A、4A、6.3A、12A、16A、32A、45A、50A、63A、100A、125A

            Auxiliary code:FK: 2 opened and 2 closed+ 1 group conversion + 1 group fault alarm

            Control voltage:M:AC220V

            Display code:B:Digital 、E:LCD

            Additional features:F:Fire protection、L:Leakage 、T:Communication、FT:Fire protection+Communication、TL:Communication+Leakage 、FLT:Fire protection+Leakage +Communication

          page top