          KLD-MR Series

          Power Factor Controller

          Power factor controllers provide effective reactive power compensation, measurement and monitoring of the power grid, which can be applied to the automatic control of low-voltage reactive power compensation systems.

          PRODUCT OVERVIEW

          Power factor is an important criterion for the assessment of electricity efficiency. Power factor correction can improve power quality, and its function, control and safety features are highly valued by many users.

          KLD-MR series power factor controller calculates the corresponding active and reactive power according to the current and voltage collected in the power distribution system, and ensures that the power factor can be adjusted in a short period of time with a minimum number of switching cycles; the control parameters can be adjusted individually at any time even during the operation.

          The power factor controller quickly identifies the system demand for reactive power. If the reactive power demand coefficient exceeds the threshold, the appropriate combination of compensation circuits will be used according to the configuration requirements of the system and the power factor controller. Intelligent power factor controllers are able to monitor the data related to the power of the equipment and distribution system, take protective measures accordingly in the case of abnormal power parameters, and shut down the operation of the equipment or compensation circuits temporarily or permanently as required.

          CONVENIENT DISASSEMBLY AND ASSEMELY

          We have designed extremely convenient snap joints on the top and bottom of the controller for convenience.

          COMPREHENSIVE PROTECTION
          AND ALARM FUNCTIONS

          The power factor controller has built-in over-voltage, under-voltage, THDi, THDu, over-temperature and other protection limits to ensure the safety of operation

          When a parameter exceeds the limit, the controller will gradually switch off, and the alarm information can be checked in the "Fault Alarm" interface; the user only needs to check the relevant parameters and adjusts the reasonable limit, and the loop will be put into operation after the power parameters of distribution system return to normal.

          REALIZE THE FUNCTION OF
          MULTI-LOOP EXPANSION

          32-channel expansion module can help customers to increase the number of circuits in multi-loop scenarios.

          When there are a large number of loops in the compensation controller, it can be matched with MR(T) 32-channel controller expansion module to expand the control terminals of the controller through communication.

          Technical Parameters

          Operation voltage AC220V/380V,45-65Hz
          Display Current I, Voltage U, Power factor cosφ, Active power P, Reactive power Q, Harmonic THD, etc.
          Number of output channels 16 channels
          Interface RS485, RJ45, Modbus Communication protocol
          Connection Pluggable terminal
          Housing Front: resin structure Rear: metal structure
          Operating temperature -25℃~+70℃
          Storage temperature -40℃~+85℃
          Ambient humidity 0%~95%, no humidity and condensing
          Protection degree IP40 for front panel, changed protection degree can be customized
          Case size 144mm(L) x144mm(W)x65mm(D)
          Execution standard EN61010-1/IEC 61610-1,EN 61326/IEC 61326
          Selection table

          Model Application Number of controller paths AC voltage(V) Over-temperature protection Hole size(mm)
          KLD-MR16-TX Combined complementary switching contactor control 16 380 Provided 138x138
          KLD-MR16-H Mixed complementary switching contactor control 16 220 Provided 138x138
          KLD-MRT16 Combined/Mixed complementary switching thyristor control 16 220 Provided 138x138
          KLD-MR16-R Intelligent Capacitor Switching Control 64 220 Provided 138x138

          Technical Parameters


          • Operation voltage:AC220V/380V,45-65Hz

            Display:Current I, Voltage U, Power factor cosφ, Active power P, Reactive power Q, Harmonic THD, etc.

            Number of output channels:16 channels

            Interface:RS485, RJ45, Modbus Communication protocol

            Connection:Pluggable terminal

            Housing:Front: resin structure Rear: metal structure

            Operating temperature:-25℃~+70℃

            Storage temperature:-40℃~+85℃

            Ambient humidity:0%~95%, no humidity and condensing

            Protection degree:IP40 for front panel, changed protection degree can be customized

            Case size:144mm(L) x144mm(W)x65mm(D)

            Execution standard:EN61010-1/IEC 61610-1,EN 61326/IEC 61326

          Selection table


          • Application:Combined complementary switching contactor control

            Number of controller paths:16

            AC voltage(V):380

            Over-temperature protection:Provided

            Hole size(mm):138x138

          • Application:Combined complementary switching contactor control

            Number of controller paths:16

            AC voltage(V):220

            Over-temperature protection:Provided

            Hole size(mm):138x138

          • Application:Combined/Mixed complementary switching thyristor control

            Number of controller paths:16

            AC voltage(V):220

            Over-temperature protection:Provided

            Hole size(mm):138x138

          • Application:Intelligent Capacitor Switching Control

            Number of controller paths:64

            AC voltage(V):220

            Over-temperature protection:Provided

            Hole size(mm):138x138