          KLD-SVG Series

          Static Var Generator

          KLD-SVG series static var generators can quickly and bi-directionally regulate the reactive power of the AC power grid, and have very fast and accurate compensation capability for the impulse reactive power.

          PRODUCT OVERVIEW

          With the development of power electronics technology, a variety of non-linear and time-varying electronic equipment are used on a large scale and the requirements for the power supply system are getting higher and higher, thus the traditional commonly used shunt capacitor compensation mode has been unable to meet the demands of controlling some of the distribution system with impulse loads (such as welding machines, rolling mills, Banbury mixers, etc.). As one of the core equipment and technology of FACTS (Flexible Alternating Current Transmission System), the Static Reactive Generator SVG is used in the distribution system to realize continuous and rapid reactive power compensation from inductive to capacitive, effectively suppressing voltage fluctuation and system oscillation, improving three-phase imbalance of loads and enhancing system stability. It is the optimal solution in the field of reactive power control.

          KLD-SVG series low-voltage static var generator provides a new type of compensation mode that makes breakthrough of the traditional capacitor and electric motor reactive power compensation theory. It integrates power electronic technology, computer technology and modern control technology, and can quickly regulate the reactive power of AC power grid. It also has very effective capability for regulating the reactive power impact, static reactive power and reactive power in under-voltage conditions, and has the functions of voltage adjustment and harmonic suppression, which is an ideal choice for stabilizing the voltage and improving the power factor. At the same time, it gains significant benefits from energy saving and consumption reduction, and capacity increase of the power supply equipments.

          DYNAMIC FAST COMPENSATION CAPABILITY

          Based on electronic inverter technology, KLD-SVG series can quickly respond to the reactive power, with a response time of less than 10ms.

          It adopts gate turn-off power electronic component (IGBT) to form a self-commutated bridge circuit, and adjusts the amplitude and phase of the output voltage on the AC side through IGBT to quickly absorb or generate the required reactive power, realizing the purpose of rapid dynamic regulation of reactive power.

          BIDIRECTIONAL REACTIVE POWER
          COMPENSATION FUNCTION

          SVG can generate the corresponding compensation current according to the inductive or capacitive load, and compensate the power factor of the system to 0.99.

          LOW-NOISE HEAT DISSIPATION DESIGN

          The module uses the fan with low noise, which not only ensures the effective dissipation of heat inside the module, but also reduces the noise of the whole equipment.

          Designed in the form of internal layered structure, each module is equipped with an independent intelligent cooling system to reduce the operating temperature of the equipment.The noise of the whole equipment is less than or equal to 60dB

          Technical Parameters

          Input
          Operating voltage 200~690V
          Operating frequency 50/60±5%Hz
          Wiring mode Three-phase three-wire、three-phase four-wire
          Performance indicators
          Power factor >0.99,configurable
          Reactive power compensation mode Dynamic continuous automatic regulation
          Full response time <10ms
          Equipment efficiency Up to97%
          *Harmonic filtering Supports low-order (3rd, 5th, 7th, 9th, 11st, 13th) harmonic compensation
          IGBT Frequency 20kHz
          Overload protection Automatic current limiting at 100% of rated output
          Compensation of three-phase unbalanced loads Provided
          *Output harmonic current ≤50% of rated power
          Mean time between failures MTBF≥150000 hours
          Self loss <2.5%
          Interface module
          Display interface New full-color display, real-time display of system harmonics and harmonic current output by equipment
          Operation interface LCD intelligent operation unit
          Display language Simplified Chinese/English
          Communication interface RS485、Modbus
          Ambient operation
          Ambient temperature -10℃~+55℃
          Storage temperature -40℃~+75℃
          Relative humidity Max. 95%RH (no condesing)
          Altitude ≤1500 meters; 1500-4000 merers, the power is reduced by 1% for every 100m increase
          Selection table

          Model Compensation capacity(kvar) Rated voltage(V) type Cooling mode
          Three-phase three-wire system
          KLD-SVG-50-3L-400V-HD 50 400 Wall-mounted, with screen Forced air-cooling
          KLD-SVG-50-3L-400V-RD 50 400 Rack-mounted, with screen Forced air-cooling
          KLD-SVG-100-3L-400V-RD 100 400 Rack-mounted, with screen Forced air-cooling
          KLD-SVG-150-3L-400V-RD 150 400 Rack-mounted, with screen Forced air-cooling
          KLD-SVG-50-3L-690V-RC 50 690 Rack-mounted, centralized monitoring and control Forced air-cooling
          KLD-SVG-100-3L-690V-RC 100 690 Rack-mounted, centralized monitoring and control Forced air-cooling
          three-phase our-wire system
          KLD-SVG-50-4L-400V-HD 50 400 Wall-mounted、with screen Forced air-cooling
          KLD-SVG-50-4L-400V-RD 50 400 Rack-mounted, with screen Forced air-cooling
          KLD-SVG-100-4L-400V-RD 100 400 Rack-mounted, with screen Forced air-cooling
          KLD-SVG-150-4L-400V-RD 150 400 Rack-mounted, with screen Forced air-cooling
          KLD-SVG-50-4L-690V-RC 50 690 Rack-mounted, centralized monitoring and control Forced air-cooling
          KLD-SVG-100-4L-690V-RC 100 690 Rack-mounted, centralized monitoring and control Forced air-cooling

          Technical Parameters


          • Operating voltage:200~690V

            Operating frequency:50/60±5%Hz

            Wiring mode:hree-phase three-wire, three-phase four-wire

          • Power factor:>0.99,configurable

            Reactive power compensation mode:Dynamic continuous automatic regulation

            Full response time:<10ms

            Equipment efficiency:Up to97%

            *Harmonic filtering:Supports low-order (3rd, 5th, 7th, 9th, 11st, 13th) harmonic compensation

            IGBT frequency:20kHz

            Overload protection:Automatic current limiting at 100% of rated output

            Compensation of three-phase unbalanced loads:Supported

            *Output harmonic current:≤50% of rated power

            Mean time between failures:MTBF≥150000 hours

            Self loss:<2.5%

          • Display interface:New full-color display, real-time display of system harmonics and harmonic current output by equipment

            Operation interface:LCD intelligent operation unit

            Display language:Simplified Chinese/English

            Communication interface:RS485、Modbus

          • >Ambient temperature:-10℃~+55℃

            Storage temperature:-40℃~+75℃

            Relative humidity:Max. 95%RH (no condesing)

            Altitude:≤1500 meters; 1500-4000 merers, the power is reduced by 1% for every 100m increase

          Selection table


          Three-phase three-wire system

          • Compensation capacity(kvar):50

            Rated voltage(V):400

            Type:Wall-mounted, with screen

            Cooling mode:Forced air-cooling

          • Compensation capacity(kvar):50

            Rated voltage(V):400

            Type:Rack-mounted, with screen

            Cooling mode:Forced air-cooling

          • Compensation capacity(kvar):100

            Rated voltage(V):400

            Type:Rack-mounted, with screen

            Cooling mode:Forced air-cooling

          Three-phase four-wire system

          • Compensation capacity(kvar):150

            Rated voltage(V):400

            Type:Rack-mounted, with screen

            Cooling mode:Forced air-cooling

          • Compensation capacity(kvar):50

            Rated voltage(V):690

            Type:Rack-mounted, centralized monitoring and control

            Cooling mode:Forced air-cooling

          • Compensation capacity(kvar):100

            Rated voltage(V):690

            Type:Rack-mounted, centralized monitoring and control

            Cooling mode:Forced air-cooling

          Three-phase four-wire system

          • Compensation capacity(kvar):50

            Rated voltage(V):400

            Type:Wall-mounted, with screen

            Cooling mode:Forced air-cooling

          • Compensation capacity(kvar):50

            Rated voltage(V):400

            Type:Rack-mounted, with screen

            Cooling mode:Forced air-cooling

          • >Compensation capacity(kvar):100

            Rated voltage(V):400

            Type:Rack-mounted, with screen

            Cooling mode:Forced air-cooling

          • Compensation capacity(kvar):150

            Rated voltage(V):400

            Type:Rack-mounted, with screen

            Cooling mode:Forced air-cooling

          • Compensation capacity(kvar):50

            Rated voltage(V):690

            Type:Rack-mounted, centralized monitoring and control

            Cooling mode:Forced air-cooling

          • Compensation capacity(kvar):100

            Rated voltage(V):690

            Type:Rack-mounted, centralized monitoring and control

            Cooling mode:Forced air-cooling