          MMINI60 Series

          DIN Rail Meter

          (Electric energy, Prepaid, Fee Control)

          Intelligent Efficient Safe Comprehensive

          PRODUCT OVERVIEW

          MINI60 series DIN rail meter adopts specialized large-scale integrated circuits and SMT technology for electric energy metering, as well as advanced three-proof (waterproof, dustproof, corrosion proof) circuit boards, featuring high reliability, strong anti-interference ability, and high-definition LCD display in segments. Its parameters such as rate period can be set and has the function of electric energy impulse output; it can be uploaded to the energy consumption system through RS485 communication interface, which greatly facilitates the automatic management of electric power consumption. It is widely used in commercial buildings, residential compounds and infrastructure, realizing intelligent control and management.

          PRODUCT CHARACTERITICS

          Space saving

          Guide rail design and modular structure make the energy meter compact and save the space.

          Accurate metering

          The electric energy meter is able to accurately measure the current and voltage, and then calculate the amount of energy consumed, ensuring an accurate record of electricity consumption.

          Multiple functions

          In addition to basic electric energy measurement, the meter is also equipped with demand measurement, data recording, remote communication and other functions. It supports a variety of communication protocols for easy integration into the smart grid and automatic building systems.

          Convenient installation

          Easy to install and replace on electrical distribution boards without additional brackets or complicated installation procedures.

          Technical Parameters

          MINI60 Series Electric Energy DIN Rail Meter

          Item Parameter
          Model MINI602X-2P(4P) MINI603(4)X-7P
          Accuracy class Class B for active power, Class 2.0 for reactive power
          Display mode LCD display
          Input voltage Network Single-phase Three-phase four-wire:3*220V/380V、3*57.7/100V; Three-phase three-wire:3*380V、3*100V
          Rated value AC 220V、AC100V AC 380V、AC220V、AC100V
          Overvoltage 1.2 times of rated value (continuous), 2 times of rated value/1 sec
          power dissipation <0.1VA (per phase)
          Impedance >1.72MΩ
          Input current Specification 2P:0.25-0.5(30)A、0.5-1(60)A 0.015-0.075(6)A、0.25-0.5(20)A、0.5-1(40)A、0.75-1(60)A、1-2(80)A、1-2(100)A
          4P:0.015-0.075(6)A、0.25-0.5(20)A、0.5-1(40)A、1-2(80)A、1-2(100)A
          Overcurrent Continuous: 1.2 times of rated value, Instantaneous: 2 times of rated value/10 secs
          Impedance <20mΩ (per phase)
          Frequency 50Hz or 60Hz
          Electric energy Positive active energy Four-quadrant energy metering
          Operating voltage Normal operating voltage range:0.9~1.1Un
          Power consumption <5VA
          Function module Electric energy impulse Impulse width: 80ms±20ms Optical coupler isolation, open collector output
          Communication interface (optional) RS485 interface, Modbus-RTU protocol or DL/T645-2007 protocol
          Operating environment Normal operating temperature:-10℃~+55℃,Working temperature limit:-20℃~+65℃
          Storage environment -20℃~+85℃,Relative humidity:≤95% (no condensing)
          Safety Insulation Resistance between signal, output terminal and casing>100MΩ
          Withstand voltage Input and output >2kV
          Overall dimensions(W*D*H) 2P:36*66*90(mm)、4P:76*74*91(mm)、7P:126*74*91(mm)
          Installation method 35mm standard guide rail mounted

          MINI60-Y Series Prepaid DIN Rail Meter

          Item Parameter
          Model MINI602X-4P-Y MINI603X-7P-Y
          MINI604X-7P-Y
          Accuracy class Class B for active power, Class 2.0 for reactive power
          Display mode LCD display
          Input voltage Network Single-phase Three-phase four-wire
          Rated value AC220V、AC100V AC3*220V/380V
          Overvoltage Continuous: 1.2 times of rated value, Instantaneous: 2 times of rated value/10 secs
          power dissipation <0.1VA (per phase)
          Impedance >1.72MΩ
          Input current Specification 0.015-0.075(6)A、0.25-0.5(20)A、0.5-1(40)A、1-2(80)A、1-2(100)A
          Overcurrent Continuous: 1.2 times of rated value, Instantaneous: 2 times of rated value/10 secs
          Impedance <2mΩ (per phase)
          Frequency 50Hz or 60Hz
          Electricity Four-quadrant energy metering
          Operating voltage Normal operating voltage range:0.9~1.1Un
          Power consumption <5VA
          Function module Electric energy impulse Impulse width: 80ms±20ms Optical coupler isolation, open collector output
          Communication interface (optional) RS485 interface, Modbus-RTU protocol, DL/T645-2007 protocol for multi-rate function
          Operating environment Normal operating temperature:-10℃~+55℃,Working temperature limit:-20℃~+65℃
          Storage environment -20℃~+85℃,Relative humidity:≤95% (no condensing))
          Safety Insulation Resistance between signal, output terminal and casing>100MΩ
          Withstand voltage Input and output >2kV
          Overall dimensions(W*D*H) 4P:76*84*94(mm)、7P:126*84*94(mm)
          Installation method 35mm standard guide rail mounted

          MINI60-F Series Fee Control DIN Rail Meter

          Item Parameter
          Model MINI602X-4P-F MINI603(4)X-7P-F
          Display mode LCD display
          Input voltage Network Single-phase Three-phase four-wire
          Rated value AC220V AC3*220V/380V
          Input current Specification 0.25-0.5(60)A、0.5-1(80)A 0.015-0.075(6)A、0.25-0.5(40)A、0.5-1(80)A
          Frequency 50Hz or 60Hz
          Electricity Four-quadrant energy metering
          Operating voltage Normal operating voltage range:0.9~1.1Un;Working voltage range limit:0.7~1.2Un
          Starting current (directly connected) 0.004lb 0.004lb directly connected, 0.002lb connected with transformer
          Creeping Hardware anti-creeping logic
          Power consumption(voltage circuit) ≤5VA ≤5VA (per phase)
          Power consumption(current circuit) <4VA <4VA (per phase)
          Function module Electric energy impulse Impulse width: 80ms±20ms Optical coupler isolation, open collector output
          Communication interface (optional) RS485 interface, Infrared communication, DL/T645-2007 protocol
          Clock error ≤0.5s/d
          Operating environment Normal operating temperature:-10℃~+45℃,Working temperature limit:-20℃~+55℃
          Storage environment -25℃~+70℃,Relative humidity:≤95% (no condensing))
          Number of rates (Multi-rate model only) 4
          Number of daily time slots (Multi-rate model only) 14
          Number of annual time zones (Multi-rate model only) 2
          Mean time between failures ≥50000h
          Overall dimensions(W*D*H) 4P:76*76*103(mm)、7P:126*76*103(mm)
          Installation method 35mm standard guide rail mounted
          Selection table

          MINI60 Series Electric Energy DIN Rail Meter

          MINI60 3 1 7P
          Product code Wiring code Function code External dimension code
          MINI60:
          DIN rail meter
          2:Single-phase
          3: Three-phase directly connected
          4:Three-phase connected via CT
          0: Four-quadrant Electric Energy + Communication
          1: Multi-function+Communication
          2: Multi-function+Multi-rate+Communication
          2P:2-digit width
          4P:4-digit width
          7P:7-digit width

          Note: Multi-function includes current, voltage, active power, frequency, reactive power, apparent power, power factor, positive active power, positive reactive power.

          MINI60-Y Series Prepaid DIN Rail Meter

          MINI60 3 1 7P Y H L
          Product code Wiring code Function code External dimension code Product type Electricity sales mode Optional functions
          MINI60:
          DIN rail meter
          2:Single-phase
          3: Three-phase directly connected
          4:Three-phase connected via CT
          1: Multi-function+Communication
          2: Multi-function+Multi-rate+Communication
          4P:4-digit width
          7P:7-digit width
          Y:Prepaid T:Remote sales
          K: IC card sales
          H:Hybrid sales
          L:Malignant load identification function
          None:No malignant load identification function

          Note: ? Multi-function includes current, voltage, active power, frequency, reactive power, apparent power, power factor, positive active energy, positive reactive energy.
          ? Electricity sales software of prepaid model is free of charge. The standard configuration is 1 card for IC card sales (YK) per meter and hybrid electricity sales (YH) per meter, remote electricity sales (YT) is not equipped with sales card by default (make a request when placing an order)

          MINI60-F Series Fee Control DIN Rail Meter

          MINI60 3 1 7P F
          Product code Wiring code Function code External dimension code Electricity sales mode
          MINI60:
          DIN rail meter
          2:Single-phase
          3: Three-phase directly connected
          4:Three-phase connected via CT
          1: Multi-function+Communication
          2: Multi-function+Multi-rate+Communication
          4P:4-digit width
          7P:7-digit width
          F: Fee control

          Note: ? Multi-function includes current, voltage, active power, frequency, reactive power, apparent power, power factor, positive active energy, positive reactive energy.
          ? Fee control meter complies with DL/T645-2007 protocol

          Technical Parameters


          MINI60 Series Electric Energy DIN Rail Meter

          • Accuracy class:Class B for active power, Class 2.0 for reactive power

            Display mode:LCD display

            Input voltage:Network:Single-phase;Rated value:AC 220V、AC100V;Overvoltage:1.2 times of rated value (continuous), 2 times of rated value/1 sec;power dissipation:<0.1VA (per phase);Impedance:>1.72MΩ;

            Input current:Specification:    2P:0.25-0.5(30)A、0.5-1(60)A /4P:0.015-0.075(6)A、0.25-0.5(20)A、0.5-1(40)A、1-2(80)A、1-2(100)A;  Overcurrent:Continuous: 1.2 times of rated value, Instantaneous: 2 times of rated value/10 secs;Impedance:<20mΩ (per phase);

            Frequency:50Hz or 60Hz

            Electricity:Positive active energy;

            Operating voltage:Normal operating voltage range:0.9~1.1Un;

            Power consumption<5VA;

            Function module:Electric energy impulse:Impulse width: 80ms±20ms Optical coupler isolation, open collector output;  Communication interface (optional):RS485 interface, Modbus-RTU protocol or DL/T645-2007 protocol;

            Operating environment:Normal operating temperature:-10℃~+55℃,Working temperature limit:-20℃~+65℃;

            Storage environment:-20℃~+85℃,Relative humidity:≤95% (no condensing);

            Safety:Insulation:Resistance between signal, output terminal and casing>100MΩ;Withstand voltage: Input and output >2kV;  Overall dimensions(W*D*H):2P:36*66*90(mm)、4P:76*74*91(mm)、7P:126*74*91(mm);

          • Accuracy class:Class B for active power, Class 2.0 for reactive power

            Display mode:LCD display

            Input voltage:Network:AC 380V、AC220V、AC100V;Rated value:AC 380V、AC220V、AC100V;Overvoltage:1.2 times of rated value (continuous), 2 times of rated value/1 sec;power dissipation:<0.1VA (per phase);Impedance:>1.72MΩ;

            Input current:Specification:0.015-0.075(6)A、0.25-0.5(20)A、0.5-1(40)A、0.75-1(60)A、1-2(80)A、1-2(100)A;  Overcurrent:Continuous: 1.2 times of rated value, Instantaneous: 2 times of rated value/10 secs;Impedance:<20mΩ (per phase);

            Frequency:50Hz or 60Hz

            Electricity:Four-quadrant energy metering;

            Operating voltage:Normal operating voltage range:0.9~1.1Un;

            Power consumption<5VA;

            Function module:Electric energy impulse:Impulse width: 80ms±20ms Optical coupler isolation, open collector output;  Communication interface (optional):RS485 interface, Modbus-RTU protocol or DL/T645-2007 protocol;

            Operating environment:Normal operating temperature:-10℃~+55℃,Working temperature limit:-20℃~+65℃;

            Storage environment:-20℃~+85℃,Relative humidity:≤95% (no condensing);

            Safety:Insulation:Resistance between signal, output terminal and casing>100MΩ;Withstand voltage: Input and output >2kV;  Overall dimensions(W*D*H):2P:36*66*90(mm)、4P:76*74*91(mm)、7P:126*74*91(mm);

          MINI60-Y Series Prepaid DIN Rail Meter

          • Accuracy class:Class B for active power, Class 2.0 for reactive power

            Display mode:LCD display

            Input voltage:Network:Single-phase;Rated value:AC220V、AC100V;Overvoltage:1.2 times of rated value (continuous), 2 times of rated value/1 sec;power dissipation:<0.1VA (per phase);Impedance:>1.72MΩ;

            Input current:Specification:0.015-0.075(6)A、0.25-0.5(20)A、0.5-1(40)A、1-2(80)A、1-2(100)A;  Overcurrent:Continuous: 1.2 times of rated value, Instantaneous: 2 times of rated value/10 secs;Impedance:<20mΩ (per phase);

            Frequency:50Hz or 60Hz

            Electricity:Four-quadrant energy metering;

            Operating voltage:Normal operating voltage range:0.9~1.1Un;

            Power consumption<5VA;

            Function module:Electric energy impulse:Impulse width: 80ms±20ms Optical coupler isolation, open collector output;  Communication interface (optional):RS485 interface, Modbus-RTU protocol, DL/T645-2007 protocol for multi-rate function;

            Operating environment:Normal operating temperature:-10℃~+55℃,Working temperature limit:-20℃~+65℃;

            Storage environment:-20℃~+85℃,Relative humidity:≤95% (no condensing));

            Safety:Insulation:Resistance between signal, output terminal and casing>100MΩ;Withstand voltage: Input and output >2kV;

            Overall dimensions(W*D*H):4P:76*84*94(mm)、7P:126*84*94(mm);

            Installation method:35mm standard guide rail mounted;

          • Accuracy class:Class B for active power, Class 2.0 for reactive power

            Display mode:LCD display

            Input voltage:Network:Three-phase four-wire;Rated value:AC3*220V/380V;Overvoltage:1.2 times of rated value (continuous), 2 times of rated value/1 sec;power dissipation:<0.1VA (per phase);Impedance:>1.72MΩ;

            Input current:Specification:0.015-0.075(6)A、0.25-0.5(20)A、0.5-1(40)A、1-2(80)A、1-2(100)A;  Overcurrent:Continuous: 1.2 times of rated value, Instantaneous: 2 times of rated value/10 secs;Impedance:<20mΩ (per phase);

            Frequency:50Hz or 60Hz

            Electricity:Four-quadrant energy metering;

            Operating voltage:Normal operating voltage range:0.9~1.1Un;

            Power consumption<5VA;

            Function module:Electric energy impulse:Impulse width: 80ms±20ms Optical coupler isolation, open collector output;  Communication interface (optional):RS485 interface, Modbus-RTU protocol, DL/T645-2007 protocol for multi-rate function;

            Operating environment:Normal operating temperature:-10℃~+55℃,Working temperature limit:-20℃~+65℃;

            Storage environment:-20℃~+85℃,Relative humidity:≤95% (no condensing));

            Safety:Insulation:Resistance between signal, output terminal and casing>100MΩ;Withstand voltage: Input and output >2kV;

            Overall dimensions(W*D*H):4P:76*84*94(mm)、7P:126*84*94(mm);

            Installation method:35mm standard guide rail mounted;

          Note: ? Multi-function includes current, voltage, active power, frequency, reactive power, apparent power, power factor, positive active energy, positive reactive energy.
          ? 72 models; the maximum additional function is 4DI/2DO/1M/R/2P.
          ? When function code A or B is selected, the maximum additional function is 4DI/2DO/1M/R.
          ?The number of DI can only be selected as 4DI or 8DI, and the number of DO can only be selected as 2DO or 4DO.

          MINI60-F Series Fee Control DIN Rail Meter

          • Display mode:LCD display;

            Input voltage:Network:Single-phase;Rated value :AC220V;Specification:0.25-0.5(60)A、0.5-1(80)A;

            Input current:Specification:0.25-0.5(60)A、0.5-1(80)A;

            Frequency :50Hz or 60Hz;

            Electricity:Four-quadrant energy metering;

            Operating voltage:Normal operating voltage range:0.9~1.1Un;Working voltage range limit:0.7~1.2Un;

            Starting current (directly connected) :0.004lb;

            Creeping:Hardware anti-creeping logic;

            Power consumption(voltage circuit):≤5VA;

            Power consumption(current circuit):<4VA;

            Function module:Electric energy impulse:Impulse width: 80ms±20ms Optical coupler isolation, open collector output;Communication interface (optional):RS485 interface, Infrared communication, DL/T645-2007 protocol;

            Clock error:≤0.5s/d;

            Operating environment:Normal operating temperature:-10℃~+45℃,Working temperature limit:-20℃~+55℃;

            Storage environment:-25℃~+70℃,Relative humidity:≤95% (no condensing));

            Number of rates (Multi-rate model only):4;

            Number of daily time slots (Multi-rate model only):14;

            Number of annual time zones (Multi-rate model only):2;

            Mean time between failures:≥50000h;

            Overall dimensions(W*D*H):4P:76*76*103(mm)、7P:126*76*103(mm);

            Installation method:35mm standard guide rail mounted;

          • Display mode:LCD display;

            Input voltage:Network:Three-phase four-wire;Rated value :AC3*220V/380V;Specification:0.015-0.075(6)A、0.25-0.5(40)A、0.5-1(80)A;

            Input current:Specification:0.25-0.5(60)A、0.5-1(80)A;

            Frequency :50Hz or 60Hz;

            Electricity:Four-quadrant energy metering;

            Operating voltage:Normal operating voltage range:0.9~1.1Un;Working voltage range limit:0.7~1.2Un;

            Starting current (directly connected) :0.004lb directly connected, 0.002lb connected with transformer;

            Creeping:Hardware anti-creeping logic;

            Power consumption(voltage circuit):≤5VA (per phase);

            Power consumption(current circuit):<4VA (per phase);

            Function module:Electric energy impulse:Impulse width: 80ms±20ms Optical coupler isolation, open collector output;Communication interface (optional):RS485 interface, Infrared communication, DL/T645-2007 protocol;

            Clock error:≤0.5s/d;

            Operating environment:Normal operating temperature:-10℃~+45℃,Working temperature limit:-20℃~+55℃;

            Storage environment:-25℃~+70℃,Relative humidity:≤95% (no condensing));

            Number of rates (Multi-rate model only):4;

            Number of daily time slots (Multi-rate model only):14;

            Number of annual time zones (Multi-rate model only):2;

            Mean time between failures:≥50000h;

            Overall dimensions(W*D*H):4P:76*76*103(mm)、7P:126*76*103(mm);

            Installation method:35mm standard guide rail mounted;

          Selection table


          • Product code :MINI60:DIN rail meter

            Wiring code:2:Single-phase;3: Three-phase directly connected ;4:Three-phase connected via CT

            Function code:0: Four-quadrant Electric Energy + Communication;1: Multi-function+Communication;2: Multi-function+Multi-rate+Communication;

            External dimension code:2P:2-digit width ;4P:4-digit width ;7P:7-digit width ;

          Note: Multi-function includes current, voltage, active power, frequency, reactive power, apparent power, power factor, positive active power, positive reactive power.

          • Product code :MINI60:DIN rail meter

            Wiring code:2:Single-phase;3: Three-phase directly connected ;4:Three-phase connected via CT

            Function code:1: Multi-function+Communication;2: Multi-function+Multi-rate+Communication;

            External dimension code:4P:4-digit width ;7P:7-digit width ;

            Product type:Y:Prepaid

            Electricity sales mode:T:Remote sales;K: IC card sales;H:Hybrid sales

            Optional functions:L:Malignant load identification function;None:No malignant load identification function;

          Note: Multi-function includes current, voltage, active power, frequency, reactive power, apparent power, power factor, positive active power, positive reactive power.
          ? Electricity sales software of prepaid model is free of charge. The standard configuration is 1 card for IC card sales (YK) per meter and hybrid electricity sales (YH) per meter, remote electricity sales (YT) is not equipped with sales card by default (make a request when placing an order)

          • Product code :MINI60:DIN rail meter

            Wiring code:2:Single-phase;3: Three-phase directly connected ;4:Three-phase connected via CT

            Function code:1: Multi-function+Communication;2: Multi-function+Multi-rate+Communication;

            External dimension code:4P:4-digit width ;7P:7-digit width ;

            Electricity sales mode:F: Fee control

          Note: ? Multi-function includes current, voltage, active power, frequency, reactive power, apparent power, power factor, positive active energy, positive reactive energy.
          ? Fee control meter complies with DL/T645-2007 protocol